46–50°C
Typical outdoor design temperature on Qatar projects. Confirm against your project specification.
Data centre & mission-critical cooling · Qatar
Chilled-water plants, precision air conditioning and controls, engineered for Qatar's climate and backed by Aermec's data centre range.
46–50°C
Typical outdoor design temperature on Qatar projects. Confirm against your project specification.
~25%
Share of a data centre's energy used by air conditioning, per Aermec's data centre brochure.
18–27°C
ASHRAE recommended server inlet temperature range.
How a cooling plant works
01 · IT load
Almost all the power a server draws ends up as heat in the room. A 1 MW IT hall needs roughly 1 MW of cooling, 24 hours a day, 365 days a year. Rack densities keep rising, and high-density AI and HPC racks push cooling closer to the rack.
02 · Heat capture
Cold air is supplied to the server inlets and hot exhaust is collected, usually with hot- or cold-aisle containment, and returned to precision air conditioners. A CRAH cools the air with a chilled-water coil; a CRAC uses its own refrigerant circuit. ASHRAE recommends a server inlet range of 18 to 27°C.
03 · Distribution
Pumps circulate chilled water between the data hall and the plant. Data centres can run warmer water than comfort cooling, which lets the chillers work less. Aermec's NSM_HWT chillers produce water up to +30°C for exactly this kind of design.
04 · Chillers
Chillers use a refrigeration cycle to pull heat out of the water. In Qatar they must reject that heat into 46 to 50°C air, so we select from certified operating limits, not nominal ratings. Aermec's NSM screw chillers are rated to +50°C outdoor air.
05 · Heat rejection
Air-cooled chillers reject heat directly through condenser coils and fans. Water-cooled plants use cooling towers or dry coolers. Cooling towers consume water, which is scarce here; adiabatic and hybrid dry coolers only use water at peak conditions.
06 · Monitoring & control
Sequencing controls share the load between chillers to stay efficient at part load. Integration with your BMS over Modbus, BACnet or LonWorks gives operators live alarms and trends. Aermec's Dynamic Set Point raises the water temperature automatically when the load allows.
07 · Redundancy
N is the capacity that meets the load. N+1 adds one spare unit, so any single chiller can fail or be serviced without loss of cooling. 2N duplicates the whole system. Redundant pumps, dual power feeds and fast restart after a power cut matter as much as the chillers.
Precision air conditioning
10–200 kW
Chilled-water precision units (CRAH)
Down-flow and up-flow, EC fans
7–183 kW
Direct-expansion precision units (CRAC)
Air- or water-cooled, DC inverter compressors, EC fans
20–40 kW
In-rack units
Direct expansion or chilled water, inside the rack row
Project-specific
Aerwall fan-wall units
AHU fed by a free-cooling chiller at high water temperature
Source: Aermec Data Centre Solutions brochure · See the precision air conditioning range ›
Chillers for data centres
The maximum outdoor air temperature decides which chillers can serve a data centre in Qatar. Turbocor oil-free chillers are highly efficient, but their published limit of +42°C is below typical Qatar design conditions, so we only propose them where Aermec confirms a suitable configuration.
| Series | Compressor | Capacity kW | Water produced | Max outdoor air | Configurations |
|---|---|---|---|---|---|
| NSM | Screw | 302–2,100 | -8 to +18°C | +50°C | Standard, free-cooling, glycol-free |
| NSM_I | Inverter screw | 285–1,342 | -8 to +15°C | +50°C | Standard, free-cooling |
| NSM_HWT | Screw, high water temp. | 306–1,600 | -5 to +30°C | +50°C | Free-cooling, glycol-free |
| NSG | Screw, R1234ze | 227–1,580 | +4 to +23°C | +48°C | Standard |
| NSG_I | Inverter screw, R1234ze | n/a | n/a | +50°C | Standard, free-cooling |
| TBA / TBG | Oil-free centrifugal (Turbocor) | 200–1,404 | +5 to +18°C | +42°C | Standard, free-cooling |
Source: Aermec Data Centre Solutions brochure (DATACENTERUY_07), read 20 Nov 2026. "n/a": not stated in the brochure.
Compressors for large data centres · 10 to 100+ MW
Cooling runs around the clock and energy is a major operating cost. For large facilities we concentrate on oil-free, magnetic-bearing centrifugal technology, with variable-speed screw as a strong alternative for Qatar's high ambient.
First choice
Oil-free magnetic-bearing centrifugal
Typical use: Large hyperscale and AI data centres.
In the range: Aermec TBA / TBG (Turbocor)
Practical alternative
Variable-speed screw
Typical use: Medium and large data centres, phased expansion and standby capacity.
In the range: Aermec NSM_I / NSG_I (inverter screw)
Very large plants
Conventional centrifugal
Typical use: Hyperscale sites with central water-cooled chiller plants.
In the range: Selected per project
Summer air can pass 45°C. Every chiller must be selected and guaranteed at the real summer design temperature, not at standard European conditions.
| Technology | Suitability for Qatar |
|---|---|
| Magnetic-bearing centrifugal | Excellent, if selected for high ambient conditions. Air-cooled units must be certified at your design temperature. |
| Variable-speed screw | Excellent, particularly for air-cooled modular plants. |
| Conventional centrifugal | Excellent in properly engineered water-cooled plants. |
| Scroll | Better suited to smaller facilities and edge data centres. |
High-density AI halls increasingly use liquid cooling, including direct-to-chip. Chillers still reject the heat, but coolant distribution units (CDUs) circulate coolant to the racks, heat exchangers separate the IT loop from the facility water loop, and redundant equipment protects against interruptions.
So we look at the whole system: chillers, pumps, heat exchangers and CDUs, not only the compressor.
Free cooling in Qatar
Free cooling uses cold outdoor air instead of the compressor. In northern Europe that can cover most of the year. Aermec quotes a pPUE as low as 1.07 for a London data centre with its Dynamic Set Point control.
That figure does not transfer to Doha. Free cooling only works when the outdoor air is colder than the water returning from the hall, which here mostly means winter nights. Warmer water designs widen that window, and free-cooling chillers can still pay back, but the case has to be modelled on hourly weather data for the site.
We run that model before we recommend it.
Aermec data centre references
London, UK · 2017
Primary financial institute data centre
6 Aermec NSM free-cooling chillers
Luanda, Angola · 2013
Unitel data centre
4 NRL chillers and 8 PWU precision air conditioners
Aermec projects, not delivered by Elec Qatar. Source: Aermec S.p.A. References Collection, entries authorised for publication.
Questions
Partly. Free cooling needs outdoor air colder than the chilled-water return. In Doha that happens mostly on winter nights. Running warmer chilled water widens the window, so it can still pay back, but it must be modelled on hourly weather data for your site. A London figure does not transfer.
Air-cooled plants use no make-up water and are simpler to maintain, which suits Qatar. Water-cooled plants are more efficient at the chiller but need cooling towers or dry coolers and, with towers, a reliable water supply. The choice depends on site, water, space and efficiency targets.
It depends on your availability target, often set by an Uptime Institute tier. Many facilities use N+1 chillers with redundant pumps and power paths. Mission-critical halls may require 2N. We size the plant to the target you set.
Aermec units are built in Italy and can be supplied with a "Made in Italy" Certificate of Origin from the Verona Chamber of Commerce. For tenders with strict origin rules, specific components such as compressors and heat exchangers can be specified from European or Italian suppliers only. Component origin depends on the model, so we confirm it per tender.
Aermec controls support Modbus, BACnet and LonWorks. We handle the integration and the commissioning tests with your controls contractor.