Data centre & mission-critical cooling · Qatar

Data centre cooling
for a 50°C summer.

Chilled-water plants, precision air conditioning and controls, engineered for Qatar's climate and backed by Aermec's data centre range.

46–50°C

Typical outdoor design temperature on Qatar projects. Confirm against your project specification.

~25%

Share of a data centre's energy used by air conditioning, per Aermec's data centre brochure.

18–27°C

ASHRAE recommended server inlet temperature range.

How a cooling plant works

Seven steps from server to sky.

Chilled-water cooling loop for a data centreServers in the data hall heat the air. A computer room air handler (CRAH) cools the air with chilled water. Pumps send the warmed water to air-cooled chillers outside, which reject the heat to the outdoor air. A standby chiller provides N+1 redundancy and a building management system monitors everything.Data hallOutdoor plant · 46–50°C design ambientIT racksHeat loadCRAHHot air in, cold air outChilled waterChiller · dutyHeat to outdoor airStandby · N+1BMS · Modbus / BACnet
Schematic. Equipment selection depends on load, site ambient and redundancy target.
  1. 01 · IT load

    Every watt in becomes heat out.

    Almost all the power a server draws ends up as heat in the room. A 1 MW IT hall needs roughly 1 MW of cooling, 24 hours a day, 365 days a year. Rack densities keep rising, and high-density AI and HPC racks push cooling closer to the rack.

  2. 02 · Heat capture

    Cold air in front, hot air out the back.

    Cold air is supplied to the server inlets and hot exhaust is collected, usually with hot- or cold-aisle containment, and returned to precision air conditioners. A CRAH cools the air with a chilled-water coil; a CRAC uses its own refrigerant circuit. ASHRAE recommends a server inlet range of 18 to 27°C.

  3. 03 · Distribution

    Water carries the heat out of the hall.

    Pumps circulate chilled water between the data hall and the plant. Data centres can run warmer water than comfort cooling, which lets the chillers work less. Aermec's NSM_HWT chillers produce water up to +30°C for exactly this kind of design.

  4. 04 · Chillers

    The heart of the plant.

    Chillers use a refrigeration cycle to pull heat out of the water. In Qatar they must reject that heat into 46 to 50°C air, so we select from certified operating limits, not nominal ratings. Aermec's NSM screw chillers are rated to +50°C outdoor air.

  5. 05 · Heat rejection

    Into the air, or into water.

    Air-cooled chillers reject heat directly through condenser coils and fans. Water-cooled plants use cooling towers or dry coolers. Cooling towers consume water, which is scarce here; adiabatic and hybrid dry coolers only use water at peak conditions.

  6. 06 · Monitoring & control

    Know before it fails.

    Sequencing controls share the load between chillers to stay efficient at part load. Integration with your BMS over Modbus, BACnet or LonWorks gives operators live alarms and trends. Aermec's Dynamic Set Point raises the water temperature automatically when the load allows.

  7. 07 · Redundancy

    Plan for the failure, not the brochure.

    N is the capacity that meets the load. N+1 adds one spare unit, so any single chiller can fail or be serviced without loss of cooling. 2N duplicates the whole system. Redundant pumps, dual power feeds and fast restart after a power cut matter as much as the chillers.

Precision air conditioning

Cooling at the rack,
the row or the room.

10–200 kW

Chilled-water precision units (CRAH)

Down-flow and up-flow, EC fans

7–183 kW

Direct-expansion precision units (CRAC)

Air- or water-cooled, DC inverter compressors, EC fans

20–40 kW

In-rack units

Direct expansion or chilled water, inside the rack row

Project-specific

Aerwall fan-wall units

AHU fed by a free-cooling chiller at high water temperature

Source: Aermec Data Centre Solutions brochure · See the precision air conditioning range ›

Chillers for data centres

Start from the
operating envelope.

The maximum outdoor air temperature decides which chillers can serve a data centre in Qatar. Turbocor oil-free chillers are highly efficient, but their published limit of +42°C is below typical Qatar design conditions, so we only propose them where Aermec confirms a suitable configuration.

SeriesCompressorCapacity kWWater producedMax outdoor airConfigurations
NSMScrew302–2,100-8 to +18°C+50°CStandard, free-cooling, glycol-free
NSM_IInverter screw285–1,342-8 to +15°C+50°CStandard, free-cooling
NSM_HWTScrew, high water temp.306–1,600-5 to +30°C+50°CFree-cooling, glycol-free
NSGScrew, R1234ze227–1,580+4 to +23°C+48°CStandard
NSG_IInverter screw, R1234zen/an/a+50°CStandard, free-cooling
TBA / TBGOil-free centrifugal (Turbocor)200–1,404+5 to +18°C+42°CStandard, free-cooling

Source: Aermec Data Centre Solutions brochure (DATACENTERUY_07), read 20 Nov 2026. "n/a": not stated in the brochure.

Compressors for large data centres · 10 to 100+ MW

Choose the compressor
for a 24/7 load.

Cooling runs around the clock and energy is a major operating cost. For large facilities we concentrate on oil-free, magnetic-bearing centrifugal technology, with variable-speed screw as a strong alternative for Qatar's high ambient.

First choice

Oil-free magnetic-bearing centrifugal

  • No lubricating oil in the circuit.
  • Excellent efficiency, especially at part load.
  • Low routine maintenance.
  • Variable-speed operation.
  • Built for continuous 24/7 cooling.

Typical use: Large hyperscale and AI data centres.

In the range: Aermec TBA / TBG (Turbocor)

Practical alternative

Variable-speed screw

  • Robust, proven technology.
  • Good performance as the load varies.
  • Suits modular chiller plants.
  • Copes well with high ambient temperatures, subject to selection.

Typical use: Medium and large data centres, phased expansion and standby capacity.

In the range: Aermec NSM_I / NSG_I (inverter screw)

Very large plants

Conventional centrifugal

  • Very large capacity per unit.
  • Excellent for central chilled-water plants.
  • Proven in large installations.
  • Oil lubrication and its maintenance remain a factor.

Typical use: Hyperscale sites with central water-cooled chiller plants.

In the range: Selected per project

Which technology in Qatar?

Summer air can pass 45°C. Every chiller must be selected and guaranteed at the real summer design temperature, not at standard European conditions.

TechnologySuitability for Qatar
Magnetic-bearing centrifugalExcellent, if selected for high ambient conditions. Air-cooled units must be certified at your design temperature.
Variable-speed screwExcellent, particularly for air-cooled modular plants.
Conventional centrifugalExcellent in properly engineered water-cooled plants.
ScrollBetter suited to smaller facilities and edge data centres.

AI data centres change the loop.

High-density AI halls increasingly use liquid cooling, including direct-to-chip. Chillers still reject the heat, but coolant distribution units (CDUs) circulate coolant to the racks, heat exchangers separate the IT loop from the facility water loop, and redundant equipment protects against interruptions.

So we look at the whole system: chillers, pumps, heat exchangers and CDUs, not only the compressor.

Free cooling in Qatar

Honest about the climate.

Free cooling uses cold outdoor air instead of the compressor. In northern Europe that can cover most of the year. Aermec quotes a pPUE as low as 1.07 for a London data centre with its Dynamic Set Point control.

That figure does not transfer to Doha. Free cooling only works when the outdoor air is colder than the water returning from the hall, which here mostly means winter nights. Warmer water designs widen that window, and free-cooling chillers can still pay back, but the case has to be modelled on hourly weather data for the site.

We run that model before we recommend it.

Aermec data centre references

Proven in data halls worldwide.

London, UK · 2017

Primary financial institute data centre

6 Aermec NSM free-cooling chillers

Luanda, Angola · 2013

Unitel data centre

4 NRL chillers and 8 PWU precision air conditioners

Aermec projects, not delivered by Elec Qatar. Source: Aermec S.p.A. References Collection, entries authorised for publication.

Questions

What specifiers ask us.

Does free cooling work in Qatar?

Partly. Free cooling needs outdoor air colder than the chilled-water return. In Doha that happens mostly on winter nights. Running warmer chilled water widens the window, so it can still pay back, but it must be modelled on hourly weather data for your site. A London figure does not transfer.

Air-cooled or water-cooled chillers for a data centre?

Air-cooled plants use no make-up water and are simpler to maintain, which suits Qatar. Water-cooled plants are more efficient at the chiller but need cooling towers or dry coolers and, with towers, a reliable water supply. The choice depends on site, water, space and efficiency targets.

What redundancy do we need: N+1 or 2N?

It depends on your availability target, often set by an Uptime Institute tier. Many facilities use N+1 chillers with redundant pumps and power paths. Mission-critical halls may require 2N. We size the plant to the target you set.

Can the equipment meet Country of Origin requirements?

Aermec units are built in Italy and can be supplied with a "Made in Italy" Certificate of Origin from the Verona Chamber of Commerce. For tenders with strict origin rules, specific components such as compressors and heat exchangers can be specified from European or Italian suppliers only. Component origin depends on the model, so we confirm it per tender.

Can Elec Qatar integrate with our BMS?

Aermec controls support Modbus, BACnet and LonWorks. We handle the integration and the commissioning tests with your controls contractor.